INBOARD / STERNDRIVE TUBING

Two types of tubing materials are available for plumbing Inboards and Sterndrives.

  1. SeaStar 3/8" outside diameter nylon tubing
  2. 3/8" outside diameter copper refrigeration tubing


Nylon Tubing

SeaStar 3/8" outside diameter nylon tubing is recommended for;

  • Inboard,
  • Sterndrive, and
  • Seadrive steering systems with SeaStar I (1.7 cubic inch/rev displacement) helms only. SeaStar 3/8" outside diameter nylon tubing is available in the following lengths:
Length
Feet
(Meters) Tubing
Part #'s
25'
50'
75'
100'
1000'
(7.6m)
(15.2m)
(22.8m)
(30.5m)
(305.0m)

HT5092
HT5095
HT5097
HT5100
HT5101


SeaStar 3/8" nylon tubing is not recommended for use in systems with SeaStar II helms or SeaStar HP helms. It is also not recommended for use in SeaStar I systems where the total tubing run exceeds 100 feet. In these cases outboard hose or 3/8" dia. copper tubing must be used.

 


Copper Tubing

Copper Tubing 3/8" outside diameter copper tubing is recommended for;

  • inboard,
  • sterndrive, and
  • seadrive steering systems with SeaStar II (2.4 cubic inch/rev displacement) helms only, or where the length of tubing run exceeds 100 feet (30.5m).

Additional SeaStar hose kit part number HF5508 is required to connect the tubing to the cylinder.

3/8" copper tubing should be obtained through a local vendor based on the following tubing specifications.

Specification for copper tubing:
Annealed Copper Refrigeration Tubing 0.032 wall thickness 3/8" outside diameter

 


To determine the required length of tubing for single and dual configurations:

From the illustrations (figures A through C), select the situation which best suits your application and note;

a) the type of drive system, and

b) the number of steering stations.

 


Single Station
  1. From the illustration which best suits your application note the number of lengths of tubing and fitting kits required.
  2. Measure along the intended path of tube routing for each of the tubing runs.
  3. Determine if 3/8" nylon tube can be used or if copper tubing is required based on lengths of tubing runs required.
  4. Total up the entire length of tubing required and round up to the next available tube kit length.

 


Figure A

Single Inboard Cylinder

Fittings required supplied with helm and cylinder

 

 


Figure B


Single Sterndrive Cylinder

Fittings required supplied with helm and cylinder

 

 


Parts List

For figures A and B
Item# Description Part # Quantity
Req.

1

3/8" Dia. Nylon or
copper tube
HT5__ As Measured

 


Additional Steering Station or Autopilot Kit
  1. Refer to illustration Figure C.
  2. Determine the location of the second station or autopilot power pack.
  3. Measure along the path of the tube routing from the upper helm pump to the second station or autopilot power pack. Multiply this length by three for the amount of tubing required.
  4. Select the tubing kit based on the total system tubing requirement.

 

 


Figure C


2nd Steering Station or Autopilot

  • A compensating line is required between helm stations or the helm and autopilot power pack.
  • All hoses should be routed with a gradual rise (particularly the compensating line) so that air will not be trapped in the lower helm station.
  • The second helm station or autopilot power pack may be connected at any location between the upper helm station and the cylinder. For existing single station installations the nylon or copper tubing may be cut and the tee fittings installed at any convienent location.
 

 


Parts List

For figures C
Item# Description Part# Quantity
Req.

1
2

3/8" Dia. Nylon or
copper tube
Fitting Kit
HT5___

HF5502
As Measured

1